• facebook
  • twitter
  • google_plus
  • mail

NATURAL GAS

HOME
  • COTATION
  • CONTACT
Français

Connecting a furnace to natural gas

Cotation

 

Discount

 

Gaz Métro's customers may be eligible for more grants for the purchase of a natural gas furnace.What it for connection of a new installation or replacement, take advantage of subsidies offered to cushion the price of your investment.

Flue Gas Venting Systems

IPEX plastic used on natural gas furnace, have been substantial changes. Special materials used for evacuation of gas are certified to ULC S636

 

To give you an idea on the outside endings (finish) see the catalog of the manufacturer IPEX

Concep of natural gas furnace

 

The heat generated by the combustion is transmitted to the ambient air through a heat exchanger. On one side of the wall, the combustion products are sucked into the exhaust duct and the other side, ambient air flows, activated by the blower. The air thus heated is routed through distribution ducts to the various places to be heated. These sheaths may be used for introducing filtered fresh air or cooled. We can then take advantage of the system to the air treatment. Temperature control is done through a thermostat installed in a control room. In recent years, the technology has advanced technology on motors and controls. These improvements allow the installation of highly efficient appliances with the possibility of modulating the power and airflow according to actual needs of the occupants. It is common today to zone this kind of system, ie d. control the set temperature in different areas or rooms of a residence, a room or a small building. 

 

 

Minimum clearance

 

Clearances from combustibles and clearances  maintenance must meet the requirements of the manufacturer. In the absence of these, refer to B149.1 existing natural gas. (4.13.2)

 

Natural gas supply

Stopcock easily accessed manual must be installed  in the pipe down or bottom or the  horizontal pipe between the pipe and the train of taps  of the appliance to natural gas. (6.18.2)

 

  

Installation surface

The furnaces to natural gas should be installed on the floor  or on a sturdy structure, level and non-combustible. If shims are needed to place the unit level, they  must be fixed permanently. (7.13.1)

BAN & RECOMMENDATION
>  No air return must be in the same room  as the furnace. (7.13.6, 8.21.4)
>Do not install a stainless steel corrugated pipe (WardFlex, TracPipe, etc.) between the shutoff valve and the unit.
> Do not install natural draft system in a  room where there would be a negative pressure.

Natural Gas Furnace

OPERATION

 Installed in each dwelling unit, the furnace can heat the air in the home and distribute heat evenly in each room.

 

Connected to an air distribution system, it allows easy and economical installation of a heat exchanger, an air conditioner and a humidification and electronic air filtration 

 

Bet on energy-efficient appliances.

Avantages

> Easy to install, the natural gas warm air furnace standardizes air temperature and quality in every room

 

>  Provides fast heat and does not dry the air.

 

>  Enables the exchange filtration and air distribution.  Ability to integrate an air conditioning unit and a humidifier.

 

> Provides the ability to evenly distribute the heat between rooms.

 

>  Greater flexibility in interior design allows with no baseboards or radiators.

 

>  Allows fresh air per piece, as required in Section 9 of the National Building Code.

TIPS FOR INSTALLATION

 

>  The integration of the unit and its pipes should be planned from the architectural design.

 

>Important: consult the manufacturer's installation manual before installing the furnace and its components

 

DO NOT FORGET

> Check the following with the installer:

 

–  Device capacity relative to the surface to be heated;

 

–  Location of the generator relative to the length allowed for evacuation vents;

 

– Outside clearance space required for installation of the drainage system;

 

–   Access to a drain to evacuate the condensation of heating and cooling.

 

>  Provide the location of the outdoor air conditioning unit (condenser) and the thermostat.

 

>Ideally, install a type of anti-vibration seal canvas on food and the return air

Soumission

Join Us

  

Served area

Montreal, Laval, South Shore, North Shore

Terrebonne, Mascouche, Repentygny, Lorraine, Lachenaie, Rosemere,

Boisbriand, Ste-Therese, Blainville, St-Eustache, Deux-Montagne, Oka, Bizard Island, Pierrefonds, Roxboro, Ahuntsic, Cartierville, Montreal-Nord, Anjou, Kirkland, Baie-d'Urfe, Beaconsfield, Pointe-Claire, Dollard-des-Ormeaux, St-Laurent, Cote St-Luc, Hampstead, Wesmount, Lasalle, Verdun, Montreal-Ouest, Montreal-Est, Pointe-aux-Trembles, Boucherville, Longeuil, Brossard, St-Hubert, Chateauguay, Delson, Ste-Catherine, St-Bruno, Chambly, Ste-Julie, Varenne, St-Jean-sur-le-Richelieu, 

 

Type of natural gas connection 

Kitchen-range      Furnace

Barbecue             Water heater

Fiereplace            Pool water heaters

Phone:     ‭(450) 629-5112‬

Mail:         pascal@bertrandsolutions.com

Adress:    937 rue Michelin, Laval (QC)  

                R.B.Q. 8002-4789-92

Send us your questions